Packaging information
CTN Szie: 40 × 30 × 20 cm
G.W./CTN:10 kg
QTY/CTN:120 pair/carton
Dear Buyers,
1. Please identify the brand & LDQuo; ShuangAn & throughout; , some products have low prices, please enter to confirm the shuangan brand.
2. Please have a clear look at the model and express price. Prices of different pressure classes are different.
3, ensure the quality, the price is lower than the vast majority of manufacturers. Jinneng power, over the years to supply power enterprises more than 5000, brand security assured use! Free shipping for more than 10 pairs! First order do not pay contact customer service, modify the freight and then pay!
Insulation gloves parameters:1.Standard for insulating gloves:LD34.1-92.2.Application range of insulating gloves: mainly used for ac voltage less than17 kv. Dc voltage less than25.55 kVWorkplace.3.Electrical insulation performance index of insulating gloves:Main electrical properties of series insulating gloves for live work modelThe ClassVerify test voltage (V)Proof - the test VoltageMaximum service voltage (V)Max - use VoltageAC/DC AC/DC2.5 kV JYST - 1 2500/4000 to 500/750JYST - 2 5 1000/1500 5000/10000 kvJYST - 3 to 10 kv 10000/20000 to 7500/11250JYST - 4 20 kv 20000/30000 17000/25500JYST - 5 30 30000/40000 26500/39750 kvJYST - 6 to 35 kv 35000/50000 to 30000/450004.Electrical insulation performance test:(1) The edge of the groove inside the glove60 mm(2The water level inside and outside the gloves should be level.5.Notes:(1After purchasing gloves, if the user finds that the gloves are exposed to rain, mildew or other abnormal changes during transportation or storage, he/she shall go to the legal testing institution for electrical performance review test.(2) The air must be checked before use. If any damage is found, it should not be used.(3) During the operation, the sleeve should be covered into the cartridge, in case of accidents.(4) After use, the inside and outside dirt should be scrubbed clean, to dry, sprinkle talc placed flat, in order to prevent compression damage, and do not put on the ground.(5) Should be stored at dry and ventilated room temperature- 15℃ to+ 30Relative humidity at ℃50%to80%In a warehouse, away from heat, away from the floor and walls20Above cm. Avoid being affected by acid, alkali, oil and other corrosive substances.Do not place in the open to avoid direct sunlight.Don't put it on the ground.(6) to use6Preventive tests must be carried out at least once a month1The article.
Acousto-optic electroscope, three-phase short-circuit grounding wire, high voltage insulating blanket, power safety tool cabinet, hand-held infrared thermometer, portable short-circuit grounding wireElectrical high voltage insulating gloves, electrical high voltage gloves, electrical high voltage gloves, electrical insulating gloves, electrical high voltage insulating gloves, electrical high voltage insulating gloves, electrical high voltage insulating gloves, insulating gloves, high voltage gloves, rubber insulating gloves, live work insulating gloves
























